Send Message
products
PRODUCTS
Home > Products > Double Beam UV Vis Spectrophotometer > LCD Double Beam Uv Visible Spectrophotometer Proportional Adjustable Bandwidth

LCD Double Beam Uv Visible Spectrophotometer Proportional Adjustable Bandwidth

Product Details

Place of Origin: CHINA

Brand Name: Macylab

Certification: ALL OF MADE IN CHINA

Model Number: UV1700SPC

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: USD3300-4100

Packaging Details: PE film then pur into wooden carton

Delivery Time: Within 5 days

Payment Terms: L/C, T/T, Western Union, MoneyGram

Supply Ability: 120SET/DAY

Get Best Price
Highlight:

adjustable double beam uv visible spectrophotometer

,

lcd double beam uv visible spectrophotometer

,

proportional adjustable bandwidth vis spectrophotometer

Product Name:
TVBN DNA Analysis Double Beam UV Vis Spectrophotometer / UV-Vis Spectrometry
Key Words:
UV-Vis Spectrometry
Wavelength Range:
190~1100nm
Band Width:
1.0nm,or 0.5 , 1, 2, 4nm Adjustable
Wavelength Accuracy:
±0.3nm
Photometric Mode:
T,A,C,E
Wavelength Setting:
Automatic
Display Mode:
6 Inches Touch Screen LCD
Stray Light:
≤0.03% τ (220nm Nal,340nm NaNO2)
Stability:
0.0005A/h@500nm
Product Name:
TVBN DNA Analysis Double Beam UV Vis Spectrophotometer / UV-Vis Spectrometry
Key Words:
UV-Vis Spectrometry
Wavelength Range:
190~1100nm
Band Width:
1.0nm,or 0.5 , 1, 2, 4nm Adjustable
Wavelength Accuracy:
±0.3nm
Photometric Mode:
T,A,C,E
Wavelength Setting:
Automatic
Display Mode:
6 Inches Touch Screen LCD
Stray Light:
≤0.03% τ (220nm Nal,340nm NaNO2)
Stability:
0.0005A/h@500nm
LCD Double Beam Uv Visible Spectrophotometer Proportional Adjustable Bandwidth

UV-1700SPC

Main Features:
UV-1700 has successfully achieved the strict requirements of high precision and high reliability measurement, which can meet the requirements of various applications, and can be used in biological research, biological industry, drug analysis, pharmaceutical, teaching and research, environmental protection, food hygiene, clinical testing, health and epidemic prevention and other fields.

 

 
Parameters:

Wavelength Range

190~1100nm

Band Width

1.8nm , 1.0nm,or 0.5 , 1, 2, 4nm adjustable

Wavelength Accuracy

±0.3nm

Photometric Accuracy

±0.3% τ(0-100%τ) ±0.002A(0~0.5A) ±0.003A(0.5A~1A)

Photometric Repeatability

0.15% τ(0-100%τ) ±0.001A(0~0.5A) ±0.0015A(0.5A~1A)

Stray Light

≤0.03% τ (220nm NaI,340nm NaNO2)

Stability

0.0005A/h@500nm

Baseline Flatness

± 0.001A

Photometric Mode

T,A,C,E

Wavelength Setting

Automatic

Display Mode

6 inches high brightness blue LCD

Light Source

Import Deuterium Lamp & Tungsten Halogen Lamp

 

The Product Pictures:
LCD Double Beam Uv Visible Spectrophotometer Proportional Adjustable Bandwidth 0
 
 
 
LCD Double Beam Uv Visible Spectrophotometer Proportional Adjustable Bandwidth 1
 
Advantages:
1

Advanced voltage stabilizing power supply matching technology, the lamp source voltage of the machine is always kept in a stable state in the operation process, which extends the life of the lamp source and increases the accuracy of the test.

2

This product uses a double exhaust system, which can timely and efficiently discharge the heat generated in the machine operation, slow down the aging process of the machine, and continuously maintain the stable test state of the machine.

3

The machine adopts an integrated shock-proof fastening chassis, the chassis is installed with 20mm cast aluminum plate, the optical devices are fixed on the same platform, to ensure the consistency of the optical path, and effectively improve the stability of the instrument and the accuracy of the reading.

 

The Factory:

LCD Double Beam Uv Visible Spectrophotometer Proportional Adjustable Bandwidth 2

LCD Double Beam Uv Visible Spectrophotometer Proportional Adjustable Bandwidth 3

LCD Double Beam Uv Visible Spectrophotometer Proportional Adjustable Bandwidth 4

FAQ:

1. Are you a factory or a trading company?
We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.

2. What about the after-sale service?
Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer’s worries.
We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.


3. What areas and applications can it be used?
It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry,life science, petrochemical industry, mining, quality control, environmental protection, etc.
 

4. Why the reading is red and reach its maximum value 3.00Abs?
Probably you use the glass cuvette in UV range.

5. Why the wavelength calibration or self checking fail?
The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.
 
EXhibition:
LCD Double Beam Uv Visible Spectrophotometer Proportional Adjustable Bandwidth 5
LCD Double Beam Uv Visible Spectrophotometer Proportional Adjustable Bandwidth 6
LCD Double Beam Uv Visible Spectrophotometer Proportional Adjustable Bandwidth 7
LCD Double Beam Uv Visible Spectrophotometer Proportional Adjustable Bandwidth 8