Macy Lab Cid Detector Faster Detection Speed Medium Step Grating ICP-6810

Product Details

Place of Origin: CHINA

Brand Name: Macylab

Certification: ALL OF MADE IN CHINA

Model Number: ICP6810

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: TALK ABOUT IT

Packaging Details: PE film then pur into wooden carton

Delivery Time: Within 5 days

Payment Terms: L/C, T/T, Western Union, MoneyGram

Supply Ability: 120SET/DAY

Get Best Price
Highlight:

faster detection speed cid detector

,

800w cid detector

Product Name:
ICP-6810
Key Words:
Faster Detection Speed
Working Frequency:
27.12MHz
Frequency Stability:
﹤0.05%
Output Power:
800W ~1600W
Output Power Stability:
≤0.05%
OMatching Way:
Automatic Matching
Light Path:
Full Reflection Imaging Light Path, Quartz Prism Two-dimensional Dispersion System
The Gas Control Module:
Advanced MFC (Mass Flow Controller)
RF Generator:
Full Solid-state RF Power Supply
Product Name:
ICP-6810
Key Words:
Faster Detection Speed
Working Frequency:
27.12MHz
Frequency Stability:
﹤0.05%
Output Power:
800W ~1600W
Output Power Stability:
≤0.05%
OMatching Way:
Automatic Matching
Light Path:
Full Reflection Imaging Light Path, Quartz Prism Two-dimensional Dispersion System
The Gas Control Module:
Advanced MFC (Mass Flow Controller)
RF Generator:
Full Solid-state RF Power Supply
Macy Lab Cid Detector Faster Detection Speed Medium Step Grating ICP-6810

ICP6810 in the nonferrous gold industry

The ICP6810 profile is introduced

ICP-6810 is Full spectrum direct reading inductively coupled plasma emission spectrometer for determining trace and trace element content in different substances (soluble in nitric acid, hydrochloric acid, hydrofluoric acid, etc.), which is widely used in environmental protection, petroleum products, rare earths, semiconductors, geology, metallurgy, chemical industry, clinical medicine, food, biological samples, criminal science, agricultural research and other fields.

 

 

Macy Lab Cid Detector Faster Detection Speed Medium  Step Grating ICP-6810 0

Macy Lab Cid Detector Faster Detection Speed Medium  Step Grating ICP-6810 1

Table 1. Main technical parameters of ICP6810

ICP6810 main technical parameters

High frequency ionizer

Working frequency 27.12MHz

Frequency stability ﹤0.05%

Output power 800W ~1600W

Output power stability ≤0.05%

OMatching way Automatic matching

Scan the light divider

light path Full reflection imaging light path, quartz prism two-dimensional dispersion system

focal distance 400mm

Graster specifications Middle step grating, 52.67, l p / mm, 64 shining angle

Resolution ratio <0.0068nm@200nm

Complete machine technical indicators

Scan the wavelength range At 165-900nm, full wavelength coverage, and measurable Al 167.120nm

Repetitiveness RSD≤1.5%

Stability RSD≤2.0%

 

 

 

ICP6810 element detection limit (g / L)

element La Ce Pr Nd Sm Eu Gd Tb
wavelength (nm) 408.672 413.765 414.311 401.225 360.946 381.967 342.247 350.917
detection limit <3.0 <5.0 <5.0 <5.0 <10.0 <1.0 <10.0 <3.0
 

 

element Dy Ho Er Tm Yb Lu Y Sc
wavelength (nm) 353.170 345.600 337.271 313.126 369.419 261.541 371.030 335.373
detection limit <3.0 <3.0 <3.0 <3.0 <1.0 <3.0 <1.0 <1.0
 

 

element Ta Nb Mn Mg B Zn Co Si
wavelength (nm) 226.230 313.340 257.610 279.553 249.773 213.856 228.616 251.611
detection limit <5.0 <5.0 <3.0 <1.0 <10.0 <3.0 <3.0 <10.0
 

 

element Ni Cd Fe Ca Mo V Be Ti
wavelength (nm) 232.003 226.502 239.562 393.366 281.615 310.230 313.041 334.941
detection limit <5.0 <3.0 <3.0 <1.0 <5.0 <5.0 <1.0 <3.0
 

 

element Cu Cr Al Zr Ag Sr Au Pt
wavelength (nm) 324.754 267.716 396.152 343.823 328.068 407.771 242.795 265.945
detection limit <3.0 <5.0 <5.0 <5.0 <3.0 <1.0 <5.0 <5.0
 

 

element Pd Ir Rh Ru Ba Li Na K
wavelength (nm) 340.458 224.268 343.489 240.272 455.403 670.784 588.995 766.490
detection limit <5.0 <10.0 <10.0 <5.0 <1.0 ≤3 ≤20 ≤60
 

 

element As Sb Bi Hg Pb Ga Os W
wavelength (nm) 228.812 206.833 223.061 253.652 220.353 294.364 225.585 207.911
detection limit ≤15 ≤15 ≤10 ≤15 ≤15 ≤10 ≤1 ≤10
 

 

element Sn Te Ta Th Tl Re Ge Se
wavelength (nm) 242.949 214.281 226.230 283.730 276.787 227.525 209.426 203.985
detection limit ≤20 ≤10 ≤5.0 ≤10 ≤30 ≤5 ≤15 ≤30
 

 

2. Precious metal sample test solution

sample measureelement Analysis instrument Sample handling overview (for reference only) remarks

Non-ferrous precious metal alloy Gold, silver, palladium, platinum, and so on ICP6810 Take 0.1-0.3g sample in a 100ml beaker, add 5ml hydrochloric acid, dissolve the sample on the heating plate to clarification, remove cold to room temperature, transferred to 50ml volumetric flask diluted with water to scale for testing. Sample blank experiment was also performed simultaneously duringthesampleprocessing process.

 

 

 

 

According to the configured standard solution concentration, directly on the computer test, the instrument can automatically give the final test results, and can be directly printed in the form of a report.

Table 3.ICP6810 and related instrument configuration

Instrument host and necessary accessories
order number definition Specifications / models manufacturer quantity remarks quantity remarks
1 Full-spectrum straight-read inductively coupled plasma emission spectrometer ICP6810 Shanghai Beauty Instrument Co., Ltd 1  
2 Automatic temperature control and circulating cooling water device     1  
3 stabilized voltage supply     1  
Instrument matching accessories
order number definition Specifications / models manufacturer quantity remarks quantity remarks
1 host     1  
2 graphoscope     1  
3 marking punch     1  
Sample processing equipment and consumables
order number definition Specifications / models manufacturer quantity remarks quantity remarks
1 Electronictemperature-controlled heating board EG-35B   1  
2 One in ten thousand is an electronic balance BS224S   1  
3 Laboratory-grade ultra-pure water machine EPED-40T   1  
4 Disposable rubber Gloves M   /  
5 Activated carbon mask     /  
6 3mlpasteurpipette 3ml   /  
7 100mlglass beaker 100ml Sichuan Shu Glass scientific Instruments /  
8 100mlGlass capacity bottle 100ml Sichuan Shu Glass scientific Instruments /  
9 5mltransfer liquid gun 0.5ml-5ml Rand, Germany 1  
10 1mltransfer liquid gun 100ul-1000ul Rand, Germany 1  
Reagent
order number definition Specifications / models manufacturer quantity remarks quantity remarks
1 hydrochloric acid GR Jiangsu Qiangsheng Chemical Co., Ltd hydrochloric acid GR Jiangsu Qiangsheng Chemical Co., Ltd hydrochloric acid GR Jiangsu Qiangsheng Chemical Co., Ltd /  
2 hydrogen nitrate GR Jiangsu Qiangsheng Chemical Co., Ltd hydrogen nitrate GR Jiangsu Qiangsheng Chemical Co., Ltd hydrogen nitrate GR Jiangsu Qiangsheng Chemical Co., Ltd /  
3 perhydrol GR Jiangsu Qiangsheng Chemical Co., Ltd perhydrol GR Jiangsu Qiangsheng Chemical Co., Ltd perhydrol GR Jiangsu Qiangsheng Chemical Co., Ltd /  
4 Standard material of each element 1000ug/ml National nonferrous Metals and electronic materials center of forecasting and analysis Standard material of each element 1000ug/ml National nonferrous Metals and electronic materials center of forecasting and analysis Standard material of each element 1000ug/ml National nonferrous Metals and electronic materials center of forecasting and analysis /  
             
 
Exhibition:
Macy Lab Cid Detector Faster Detection Speed Medium  Step Grating ICP-6810 2
 

Macy Lab Cid Detector Faster Detection Speed Medium  Step Grating ICP-6810 3

Macy Lab Cid Detector Faster Detection Speed Medium  Step Grating ICP-6810 4

 

The Company:

Macy Lab Cid Detector Faster Detection Speed Medium  Step Grating ICP-6810 5

The Factory:

Macy Lab Cid Detector Faster Detection Speed Medium  Step Grating ICP-6810 6

 

Contact Us:

Macy Lab Cid Detector Faster Detection Speed Medium  Step Grating ICP-6810 7